1 11
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis
Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis

Dionex PDA-1 Photodiode Array Detector, High Resolution, 1-nm UV/Vis

sku: 3371132
1 In Stock

Operated and passed basic function checks at intake, with no error codes. Light to moderate cosmetic wear from prior use. Not reconditioned.

Dionex

PDA-1
US • West Coast US - R
AS-IS
$1.00
$2,500.00
-100% OFF
Make Offer Enquiry Here
Add to cart Download flyer

Details

  • Category
    Analytical
  • Dimension
    18.0in x 15.0in x 7.0in
  • Serial
    08070497
  • Shipping Type
    FedEx Ground
  • Voltage / Hertz
    120V/220V / 50Hz/60Hz

Description

The Dionex PDA-1 is a high-resolution, 1024-element photodiode array detector offering exceptional accuracy and performance for sensitive and accurate library searches and peak purity analyses. It delivers 1-nm resolution with the noise and drift performance typically found in monochrometer-based detectors. This unit is in very good condition, having been tested for functionality with some minor cosmetic wear from normal use. Operating with Chromeleon software (not included), it provides comprehensive UV and Vis application support across a wavelength range of 190-800 nm. It features low noise and high light intensity with deuterium and tungsten lamps, along with fast wavelength verification via an integrated holmium oxide filter. The PDA-1 supports reliable data collection with low baseline drift and is compatible with alternate programmable data collection through four analog outputs.


Key Features
  • 1024-element photodiode array
  • 1-nm resolution
  • 190-800 nm wavelength range
  • Low noise and high light intensity
  • Deuterium and tungsten lamps
  • Built-in holmium oxide filter
  • Supports Chromeleon software
  • Low baseline drift (< 500 AU/h)
  • Front access to prealigned cells and lamps

Specifications
  • 1024-element photodiode array
  • 1-nm resolution
  • Wavelength range: 190-800 nm
  • Deuterium and tungsten lamps
  • Low baseline drift: < 500 AU/h
  • 4 analog outputs
  • Compatible with Chromeleon software (version 6.6 or higher)
  • Power requirements: 120V/220V, 50Hz/60Hz

Weight

Imperial: 37.2 Pounds

Metric: 16.87 Kilograms


Shipping Dimensions

Imperial: 21.6 lb x 18.0 lb x 8.4 lb

Metric: 54.86 cm x 45.72 cm x 21.34 cm


Harmonized Code

902730


Harmonized Code Details

902730 - Spectrometers, spectrophotometers and spectrographs using optical radiations such as UV, visible, IR. This code is used because the Dionex PDA-1 operates within the UV/Vis range, aligning with instruments categorized under spectrophotometers.